Abstract

Rainfall simulator is a tool that allows you to create artificial rain simulation as you wish.  Rainfall simulator can be used to study runoff, erosion, infiltration, and other events in hydrological processes on a laboratory scale.  The purpose of the study was determine the performance of the portable rainfall simulator that had been made with test parameters, namely the discharge radiance value, nozzle constanta, and uniformity coefficient.  The test carried out using three variatons of pump pressure treatment, namelay 1.0, 1.3, and 1.6 bar and each treatment was repeated 3 times with a test time of 7.5 minutes.  The test result show that the portable rainfall simulator can produce water discharge with uniformity level (CU) greather than 70%.  The best pump pressure for the highest uniformity of transmission is 1.6 bar. The pumping pressure affects the water discharge with a uniformity coefficient value (CU), the greather the pump pressure, the greather the water discharge value, and the uniformity coefficient value (CU). The type of nozzle used is good enough to be used as a transmitter from the rainfall simulator that was made.

 

Keywords: Coefficient Uniformity (CU), Discharge, Nozzle, Rain, Rainfall Simulator, Water.

Downloads

Download data is not yet available.

References

Banuwa, I. S. 2013. Erosi. Kencana Prenada Media Group. Jakarta.

Blanquies, L., M. Scharff, and B. Hallock. 2007. The Design and Construction of Rainfall Simulator. Cal Poly State University San Luis Obispo. California.

James, L. G., 1988. Principles of Farm Irrigation System Design. Published Simultaneously. Washington D.C.

Kartasapoetra, A.G., dan M.M.Sutedjo. 2010. Teknologi Konservasi Tanah dan Air. Rineka Cipta. Jakarta.

Keller, J and R.D. Bleisner. 1990. Sprinkler and Trickle Irrigation. AVI Publishing Company, Inc. New York, USA.

Khairiah, N. I. 2004. Evaluasi Kinerja Penggunaan Air Irigasi Sprinkler Studi Kasus di Kabupaten Enrekang. (Skripsi). Universitas Hasanuddin. Makasar.

Martinez-Mena, M., R. Abadia, V. Castillo, Y.J. Albaladejo. 2001. Disefio experimental mediante lluvia simulada para el estudio de los cambios en la erosi6n del suelo durante la tormenta. Rev. C. & G. 15(1-2):31-43.

Merriam, J.L. 1980. Evaluation Irrigation System and Practice. Irrigation Prctice. Polytecnic State University. San Luis Obispo, California.

Moore, I. D., M. C. Hirchi, and B. J. Barfield. 1983. Kentacy Rainfall Simulator. Transaction of The ASAE 3:1085-1089.

Puspitarini, H. D. 2007. Pengaruh Tekanan dan Tinggi Pipa Riser Terhadap Produksi Tanaman Jeruk (Citrus sinesis) dengan Sistem Irigasi Curah (Sprinkler Irrigation). (Skripsi). Universitas Brawijaya. Malang.

Soemarto.C.D. 1987. Hidrologi Teknik. Usaha Nasional. Surabaya.

Thomas, N.P., A. Samir., and El Swaify. 1989. Construction and Calibration of Rainfall Simulator. Journal of Agricultural Engineering 43: 1-9.

Downloads

Published

2022-10-10

How to Cite

Ridwan, R., Oktafri, O., Amin, M., & Ardila, M. (2022). Uji Kinerja Portable Rainfall Simulator pada Berbagai Tekanan Pompa. Jurnal Agricultural Biosystem Engineering, 1(3), 342–348. https://doi.org/10.23960/jabe.v1i3.6330